Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
9.
Braz J Cardiovasc Surg ; 35(1): 91-99, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32270965

RESUMEN

The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.


Asunto(s)
Arterias Mamarias , Vena Safena , Puente de Arteria Coronaria , Humanos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
10.
Rev. bras. cir. cardiovasc ; 35(1): 91-99, Jan.-Feb. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1092466

RESUMEN

Abstract The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.


Asunto(s)
Humanos , Vena Safena , Arterias Mamarias , Grado de Desobstrucción Vascular , Puente de Arteria Coronaria , Resultado del Tratamiento
11.
Braz J Cardiovasc Surg ; 34(4): 480-483, 2019 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-31454203

RESUMEN

The saphenous vein (SV) is the most commonly used conduit for coronary artery bypass surgery (CABG) and the second conduit of choice in Brazil and many other countries. The radial artery (RA) is suggested, by some, to be superior to SV grafts, although its use in the USA declined over a 10 year period. The patency of SV grafts (SVG) is improved when the vein is harvested with minimal trauma using the no-touch (NT) technique. This improved performance is due to the preservation of the outer pedicle surrounding the SV and reduction in vascular damage that occurs when using conventional techniques (CT) of harvesting. While the patency of NT SVGs has been shown superior to the RA at 36 months in one study, data from the RADIAL trial suggests the RA to be the superior conduit. When additional data using NT SVG is included in this trial the difference in risk of graft occlusion between the RA and SV grafts dissipates with there no longer being a significant difference in patency between conduits. The importance of preserving SV structure and the impact of NT harvesting on conduit choice for CABG patients are discussed in this short review.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Arteria Radial/trasplante , Vena Safena/trasplante , Brasil , Humanos , Metaanálisis como Asunto , Insuficiencia del Tratamiento , Grado de Desobstrucción Vascular
12.
Rev. bras. cir. cardiovasc ; 34(4): 480-483, July-Aug. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1020495

RESUMEN

Abstract The saphenous vein (SV) is the most commonly used conduit for coronary artery bypass surgery (CABG) and the second conduit of choice in Brazil and many other countries. The radial artery (RA) is suggested, by some, to be superior to SV grafts, although its use in the USA declined over a 10 year period. The patency of SV grafts (SVG) is improved when the vein is harvested with minimal trauma using the no-touch (NT) technique. This improved performance is due to the preservation of the outer pedicle surrounding the SV and reduction in vascular damage that occurs when using conventional techniques (CT) of harvesting. While the patency of NT SVGs has been shown superior to the RA at 36 months in one study, data from the RADIAL trial suggests the RA to be the superior conduit. When additional data using NT SVG is included in this trial the difference in risk of graft occlusion between the RA and SV grafts dissipates with there no longer being a significant difference in patency between conduits. The importance of preserving SV structure and the impact of NT harvesting on conduit choice for CABG patients are discussed in this short review.


Asunto(s)
Humanos , Vena Safena/trasplante , Enfermedad de la Arteria Coronaria/cirugía , Puente de Arteria Coronaria/métodos , Arteria Radial/trasplante , Grado de Desobstrucción Vascular , Brasil , Metaanálisis como Asunto , Insuficiencia del Tratamiento
13.
Braz J Cardiovasc Surg ; 34(1): 98-100, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30810681

RESUMEN

With more than 800,000 coronary artery bypass grafting (CABG) operations annually worldwide and the saphenous vein being the most common conduit used, there is no question that improving saphenous vein graft patency is one of the most important tasks in CABG. This video describes the no-touch harvesting procedure of the saphenous vein on an 80-year old man with hypertension, hyperlipidemia and a previous myocardial infarction with percutaneous coronary intervention to the right coronary artery. He was complaining of exertional chest pain and was diagnosed with stable angina pectoris. The coronary angiography showed advanced three vessel disease with significant stenoses in the left anterior descending (LAD) artery, two marginal arteries (MAs) and the posterior descending artery (PDA), in addition to an occluded diagonal artery (DA). The patient received a triple sequential no-touch vein graft to the PDA and two MAs together with a double sequential no-touch vein graft to the DA and LAD. A vein graft was used to bypass the LAD due to the age of the patient and the low degree of stenosis in the LAD. The no-touch harvesting technique is described in detail in the film with complete narration. A follow-up of this patient was performed at three months both clinically and with a computed tomography angiography (CTA). No angina pectoris symptoms were reported by the patient and the wounds in the chest and lower limb were completely healed. The CTA showed patent no-touch saphenous vein grafts to all the distal anastomoses.


Asunto(s)
Puente de Arteria Coronaria/métodos , Vena Safena/trasplante , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/cirugía , Humanos , Masculino , Reproducibilidad de los Resultados , Resultado del Tratamiento
14.
Rev. bras. cir. cardiovasc ; 34(1): 98-100, Jan.-Feb. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-985241

RESUMEN

Abstract With more than 800,000 coronary artery bypass grafting (CABG) operations annually worldwide and the saphenous vein being the most common conduit used, there is no question that improving saphenous vein graft patency is one of the most important tasks in CABG. This video describes the no-touch harvesting procedure of the saphenous vein on an 80-year old man with hypertension, hyperlipidemia and a previous myocardial infarction with percutaneous coronary intervention to the right coronary artery. He was complaining of exertional chest pain and was diagnosed with stable angina pectoris. The coronary angiography showed advanced three vessel disease with significant stenoses in the left anterior descending (LAD) artery, two marginal arteries (MAs) and the posterior descending artery (PDA), in addition to an occluded diagonal artery (DA). The patient received a triple sequential no-touch vein graft to the PDA and two MAs together with a double sequential no-touch vein graft to the DA and LAD. A vein graft was used to bypass the LAD due to the age of the patient and the low degree of stenosis in the LAD. The no-touch harvesting technique is described in detail in the film with complete narration. A follow-up of this patient was performed at three months both clinically and with a computed tomography angiography (CTA). No angina pectoris symptoms were reported by the patient and the wounds in the chest and lower limb were completely healed. The CTA showed patent no-touch saphenous vein grafts to all the distal anastomoses.


Asunto(s)
Humanos , Masculino , Anciano de 80 o más Años , Vena Safena/trasplante , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Reproducibilidad de los Resultados , Resultado del Tratamiento , Angiografía Coronaria/métodos , Estenosis Coronaria/cirugía , Angiografía por Tomografía Computarizada/métodos
16.
Braz J Cardiovasc Surg ; 31(2): 115-9, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-27556309

RESUMEN

INTRODUCTION: Optimal surgical management for acute type A aortic dissection (AAAD) remains unclear. The in-hospital mortality rate is still high (15%), and the intraoperative bleeding is an independent risk factor for hospital mortality. OBJECTIVE: The aim of our study was describe a new method for aortic anastomosis in the repair of AAAD and report the hospital mortality and bleeding complications. METHODS: Between January 2008 and November 2014, 24 patients, 16 male, median age 62 years, underwent surgical treatment of AAAD. The surgical technique consisted of intussusception of a Dacron tube in the dissected aorta, which is anastomosed with a first line of 2-0 polyester everting mattress suture and a second line of 3-0 polypropylene running suture placed at the outermost side. Open distal anastomosis was performed with bilateral selective antegrade cerebral perfusion in 13 (54.1%) patients. RESULTS: Cardiopulmonary bypass and aortic clamping time ranged from 75 to 135 min (mean=85 min) and 60 to 100 min (mean=67 min), respectively. The systemic circulatory arrest ranged from 29 to 60 min (mean=44.5 min). One (4.1%) patient required reoperation for bleeding, due to the use of preoperative clopidogrel. The postoperative bleeding was 382-1270 ml (mean=654 ml). We used an average of 4.2 units of red blood cells/patient. There were two (8.3%) hospital deaths, one due to intraoperative bleeding and another due to mesenteric ischemia. The average length of stay in the intensive care unit and hospital was 44 hours and 6.7 days, respectively. CONCLUSION: This new method for surgical correction of AAAD was reproducible and resulted in satisfactory clinical outcomes.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Hemorragia Posoperatoria/cirugía , Anciano , Anciano de 80 o más Años , Disección Aórtica/mortalidad , Aorta/trasplante , Aneurisma de la Aorta/mortalidad , Prótesis Vascular/estadística & datos numéricos , Implantación de Prótesis Vascular/mortalidad , Brasil , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Periodo Perioperatorio/estadística & datos numéricos , Tereftalatos Polietilenos/uso terapéutico , Hemorragia Posoperatoria/mortalidad , Datos Preliminares , Suecia , Resultado del Tratamiento
17.
Rev. bras. cir. cardiovasc ; 31(2): 115-119, Mar.-Apr. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-792655

RESUMEN

Abstract Introduction: Optimal surgical management for acute type A aortic dissection (AAAD) remains unclear. The in-hospital mortality rate is still high (15%), and the intraoperative bleeding is an independent risk factor for hospital mortality. Objective: The aim of our study was describe a new method for aortic anastomosis in the repair of AAAD and report the hospital mortality and bleeding complications. Methods: Between January 2008 and November 2014, 24 patients, 16 male, median age 62 years, underwent surgical treatment of AAAD. The surgical technique consisted of intussusception of a Dacron tube in the dissected aorta, which is anastomosed with a first line of 2-0 polyester everting mattress suture and a second line of 3-0 polypropylene running suture placed at the outermost side. Open distal anastomosis was performed with bilateral selective antegrade cerebral perfusion in 13 (54.1%) patients. Results: Cardiopulmonary bypass and aortic clamping time ranged from 75 to 135 min (mean=85 min) and 60 to 100 min (mean=67 min), respectively. The systemic circulatory arrest ranged from 29 to 60 min (mean=44.5 min). One (4.1%) patient required reoperation for bleeding, due to the use of preoperative clopidogrel. The postoperative bleeding was 382-1270 ml (mean=654 ml). We used an average of 4.2 units of red blood cells/patient. There were two (8.3%) hospital deaths, one due to intraoperative bleeding and another due to mesenteric ischemia. The average length of stay in the intensive care unit and hospital was 44 hours and 6.7 days, respectively. Conclusion: This new method for surgical correction of AAAD was reproducible and resulted in satisfactory clinical outcomes.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/cirugía , Hemorragia Posoperatoria/cirugía , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/estadística & datos numéricos , Disección Aórtica/cirugía , Aorta/trasplante , Aneurisma de la Aorta/mortalidad , Suecia , Brasil , Resultado del Tratamiento , Mortalidad Hospitalaria , Tereftalatos Polietilenos/uso terapéutico , Hemorragia Posoperatoria/mortalidad , Implantación de Prótesis Vascular/mortalidad , Periodo Perioperatorio/estadística & datos numéricos , Datos Preliminares , Disección Aórtica/mortalidad
19.
Rev Bras Cir Cardiovasc ; 27(1): 110-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22729308

RESUMEN

BACKGROUND: There is a growing need to improve myocardial protection, which will lead to better performance of cardiac operations and reduce morbidity and mortality. Therefore, the objective of this study was to compare the efficacy of myocardial protection solution using both intracellular and extracellular crystalloid type regarding the performance of the electrical conduction system, left ventricular contractility and edema, after being subjected to ischemic arrest and reperfusion. METHODS: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37ºC, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10ºC for 5 min and kept for 2 h in static ischemia at 20ºC in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05. RESULTS: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/ dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema. CONCLUSION: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.


Asunto(s)
Soluciones Cardiopléjicas/farmacología , Edema Cardíaco/patología , Sistema de Conducción Cardíaco/efectos de los fármacos , Trasplante de Corazón , Soluciones Isotónicas/farmacología , Contracción Miocárdica/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos , Análisis de Varianza , Animales , Bicarbonatos/farmacología , Cloruro de Calcio/farmacología , Soluciones Cristaloides , Disacáridos/farmacología , Electrólitos/farmacología , Glucosa/farmacología , Glutamatos/farmacología , Glutatión/farmacología , Paro Cardíaco Inducido/métodos , Hemodinámica/efectos de los fármacos , Histidina/farmacología , Magnesio/farmacología , Masculino , Manitol/farmacología , Modelos Animales , Daño por Reperfusión Miocárdica/prevención & control , Preservación de Órganos/métodos , Cloruro de Potasio/farmacología , Procaína/farmacología , Distribución Aleatoria , Ratas , Ratas Wistar , Cloruro de Sodio/farmacología , Trometamina/farmacología
20.
Rev. bras. cir. cardiovasc ; 27(1): 110-116, jan.-mar. 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-638658

RESUMEN

BACKGROUND: There is a growing need to improve myocardial protection, which will lead to better performance of cardiac operations and reduce morbidity and mortality. Therefore, the objective of this study was to compare the efficacy of myocardial protection solution using both intracellular and extracellular crystalloid type regarding the performance of the electrical conduction system, left ventricular contractility and edema, after being subjected to ischemic arrest and reperfusion. METHODS: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37ºC, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10ºC for 5 min and kept for 2 h in static ischemia at 20ºC in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05. RESULTS: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/ dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema. CONCLUSION: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.


INTRODUÇÃO: Existe crescente necessidade de aprimorar a proteção miocárdica, para melhor desempenho das operações cardíacas e diminuição da morbimortalidade. Portanto, o objetivo deste estudo foi comparar a eficácia da proteção miocárdica usando tanto solução cristaloide tipo intracelular como extracelular quanto ao desempenho do sistema de condução elétrica, contratilidade do ventrículo esquerdo e edema, após parada isquêmica e posterior reperfusão. MÉTODOS: Corações isolados de ratos Wistar foram montados em Langendorff e aleatoriamente divididos em quatro grupos. de acordo com as soluções cardioprotetoras utilizadas Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1(STH-1) e Celsior (CEL). Após a estabilização com KHB a 37ºC, valores basais (controle) foram coletados para frequência cardíaca (FC), pressão sistólica do ventrículo esquerdo (PSVE), derivada máxima de aumento da pressão ventricular esquerda (+dP/dt), derivada máxima de queda da pressão ventricular esquerda (-dP/dt) e fluxo coronariano (FCo). Os corações foram então perfundidos a 10ºC por 5 min e mantidos por 2 h em isquemia estática a 20ºC em cada solução cardioprotetora. Avaliação dos dados foi por análise de variância inteiramente casualizados em One-Way ANOVA e teste de Tukey para comparações múltiplas. O nível de significância estatística escolhido foi P<0,05. RESULTADOS: Houve recuperação da FC com todas as soluções utilizadas. A avaliação da contratilidade ventricular esquerda (PSVE, +dP/dt e -dP/dt) demonstrou que o tratamento com a solução CEL foi melhor em comparação às outras soluções. Ao analisar o CF, a solução HTK indicou melhor proteção contra edema. CONCLUSÃO: Apesar das soluções cristaloides cardioprotetoras estudadas não serem capazes de suprimir os efeitos deletérios da isquemia e reperfusão no coração de ratos, a solução CEL apresentou resultado superior seguido por HTK>KHB>STH-1.


Asunto(s)
Animales , Masculino , Ratas , Soluciones Cardiopléjicas/farmacología , Edema Cardíaco/patología , Trasplante de Corazón , Sistema de Conducción Cardíaco/efectos de los fármacos , Soluciones Isotónicas/farmacología , Contracción Miocárdica/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos , Análisis de Varianza , Bicarbonatos/farmacología , Cloruro de Calcio/farmacología , Disacáridos/farmacología , Electrólitos/farmacología , Glucosa/farmacología , Glutamatos/farmacología , Glutatión/farmacología , Paro Cardíaco Inducido/métodos , Hemodinámica/efectos de los fármacos , Histidina/farmacología , Modelos Animales , Magnesio/farmacología , Manitol/farmacología , Daño por Reperfusión Miocárdica/prevención & control , Preservación de Órganos/métodos , Cloruro de Potasio/farmacología , Procaína/farmacología , Distribución Aleatoria , Ratas Wistar , Cloruro de Sodio/farmacología , Trometamina/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...